9. Which hand-held programmers work with VSI?
We currently have 3 models of hand-held programmers that work with the VSI controller. The most common of these is the PP1a, our part number, D49510. To ensure full compatibility with VSI, however, the programmer must be at version 6 or later. This 'issue' number is shown on the PP1a product label, e.g. D49510/'7'. The chief benefit of this programmer is that it will also work with Pilot, Pilot+ & VR2. Old PP1a's can be sent back to our Customer Services Department to be upgraded, free of charge. The other hand-held programmers that will work with VSI are PP1b's, our part numbers 'D49511' & 'D50172'. These are the engineering versions of the PP1a and allow access to more parameters such as drive inhibits & motor compensation, (they will also erase fault logs). The majority of our customers that require this level of access, however, generally choose to use the PC based version of the programmer. This software, our part number, 'D50145', offers considerable benefits in terms of speed, ease of use & cost. It also works with Pilot+, VR2 and two of our scooter products, the Egis & S-drive. |